How to connect a machine in a panel with your own hands - installation diagram and selection of installation location for the machine at the entrance from above or below


Location of the electrical panel in the room

It is important to decide on the installation location of the shield. Its location requires constant access; the switchboard door must not be blocked by foreign objects.

In most cases, the shield is mounted near the entrance to the house, or already inside, but immediately in the corridor of the house or apartment. This simplifies the installation of the cable supplying voltage to the room.

  • The height of the shield is determined at the eye level of the residents of the home. This arrangement is necessary for the convenience of taking meter readings when paying for electricity.
  • Previously, in not-so-distant times, meters with automatic machines were installed on a wooden plank on the wall.
  • Although their location was usually under the ceiling, it is undesirable to do so. In the shield, the entire structure will be in a safer position.

Modern electrical panels have high protection classes, a good solid base, and a lock with a key. What is an obstacle for small household members to enter there.

In a private house, when placing the panel, the location of the high-voltage line from where the cable will be supplied to the room is taken into account.

Installation of new circuit breakers to replace old ones

I will say right away, responding to the claims of beauty enthusiasts. This is not Instagram, where the main thing is the picture. In my blog I show not gloss, photoshop and beauty, but real life. But in real life, anything can happen - crooked, askew, dirty, and dangerous.

Those who are spoiled by perfect Instagram pictures and pretentious chicks are definitely not for me. Come to me for real life without embellishment.

So, we don’t throw away the old AVs yet (they will be useful for the review), but we start installing the new ones from the DIN rail:

DIN rail for new machines in the panel

You can see one suitable wire (after the meter) 4 mm2 from below, and two going into the apartment.

I install new AVs, Schneider Electric Easy 9 with a rated current of 16 A and shutdown characteristic “C”:

New Schneider Electric assault rifles to replace the old Soviet AB25M

Why are there 2 wires, and the third one is wrapped with electrical tape? The third wire is intended for a powerful kitchen outlet, and is walled up somewhere under the tiles and kitchen units in the apartment. I installed the third AB, one might say, in reserve, especially since it was purchased in advance.

New Schneider machines, connection from above

Why Schneider and not IEK or ABB? I believe that 90% of the success and duration of operation of an electrical panel depends not on components, but on correct calculation, quality of installation and proper operation. This is exactly what I answer when people ask me “which brand should I choose?”

By the way, recently there was an article on the blog about how I went to Moscow at the invitation of IEK. The article is a detailed report of what was shown and told there.

Look at the ABB machine to the right with a rating of C25 - two wires are connected to its upper terminal. When the aluminum starts to burn, and this will definitely happen, bewilderment will arise: “How so, this is ABB! Probably fake!” Reasons why this terminal will light up?

  1. The current can be 25 x 1.45 = 36 A for an hour, taking into account the time-current characteristics and the fact that the temperature in the entrance drops significantly in winter.
  2. The wires are most likely not stripped and are not pulled through periodically.

I carefully clean the wires and make a loop to increase the contact area. In addition, the current through the contact (and through the wire, of course) is limited by the rating of the machine.

Industrial or homemade shield?

Nowadays different shields are sold. All kinds of shapes and sizes. They have either a primed metal, painted base or a plastic base. There are also brushes with internal factory filling. There are designs available for individual order.

But, if the shield installer has certain skills, then it is better to install the internal parts yourself, at your own discretion. The more experience, the more competently the installation of the structure in a certain volume of the electrical panel will be completed.

Connection diagram of circuit breakers.

Before starting work on installing the machines, you need to familiarize yourself in detail with their schematic data. Different design elements in the shield have their own designations.

Main parts used in the shield

Introductory machine. Used to protect the entire wire circuit.

  • The main cable is connected to its contacts.
  • It is possible to install a switch in front of the machine.
  • When the switch opens, you can always repair or replace any component in the electrical panel.

Do not forget to connect the power cable to the switch at the same time.

Counter

This device is installed after the machines according to the scheme. Its main task is to display the amount of energy consumed. If necessary, it can be placed separately from the electrical panel.

Residual current device

The purpose of this device is to protect against fire and electric shock. In ordinary, small houses or apartments, one RCD is installed. It is enough to handle the entire electrical current load in the room. But in the case when the calculation of energy consumption is large, up to several such devices are installed additionally.

Linear automata

They carry out their work in each individual sector of the common premises. In the event of a short circuit or high voltage, they are automatically triggered, disconnecting from the main electrical circuit. They often save you from heavy loads in room wiring when you turn on a large number of electrical appliances.

Differential machines.

They are used to protect electrical appliances on individual lines, instead of several main circuit breakers.

Mounting rail.

It looks like a metal strip. Fastening is carried out to the back of the shield. The number of rails depends on the design of the electrical panel. The more spacious the box, the more modules and slats can be installed in it. To select it correctly, first study the connection diagram of the parts.

Comb.

Has a switching function in the panel. Grounding and neutral connects each other.

Distribution bus.

This part has reliable insulation. Thanks to its special design, it connects machines for different purposes. They have good fixation, which allows high-quality fastening of the ends of the wires. They are used for both zero and phase.

Changing Soviet machine guns

I don’t know why it was necessary to install 25 A automatic machines in Soviet apartments? This only added more work to the electricians from the housing office during short circuits, who were present quite often, and there were no particularly powerful consumers in the apartments. What did you have to load this machine with in order for it to knock out? Should we include 10 refrigerators? Or several stoves? The wires will melt before this old guy can break them off!

The paradox is that there were almost no overloads (there was nothing special to load), but short circuits occurred quite often. But the AB25M automatic machine, which is discussed in the article, saves only from overloads, but not from short circuits - it simply does not have an electromagnetic release! But I got ahead of myself, let’s continue in order.

This is what the electrical panel on the landing of a standard Soviet 9-story panel building looked like over 30 years of work:

Electrical panel in the entrance of a panel house. I think this is a painfully familiar picture to many of my readers...

Closer view of the area where you will be working:

Vending machines in a panel at the entrance. Mine are top left, AB25M

Closer - the upper terminals of my machines and the “zero bus”:

Upper terminals of Soviet AB25M assault rifles

Bottom view:

Bottom terminals of Soviet automatic machines and input switch

My area of ​​responsibility is 3 AB25M automatic machines and a batch input switch (on the left).

Please note (although many people are aware, I know) - there have been no handles on switches for many years, and this situation is everywhere. The fact is that the design is very inconvenient - to get to the machines, you need to remove the cover, and to do this, remove these handles from the switches, and to do this, unscrew 4 M4 screws (not to mention the screws holding the cover). Screws are lost, handles are thrown away, and shutdown is usually done with pliers, which does not contribute to efficiency and safety (((

General purpose of the machine

A circuit breaker is a device whose function is fire protection. Arising from a wiring fire experiencing an overload in the network.

Triggering of the machine leads to a break in the circuit. It turns off power in the following cases:

  • Wiring short circuit
  • Sudden power surge in the network (each machine has its own overvoltage threshold)

When wiring has different cross-sections, automatic machines of different power are used, which allows you to control the load on a certain section of the wiring.

Why change Soviet machine guns to modern ones?

I was planning to do some electrical upgrades in the apartment, but I was afraid that an unintentional short circuit might cause a big bang. After all, even manual shutdown occurred with great effort and creaking. Therefore, I was not at all sure that during an overcurrent the shutdown would occur exactly where it was needed - inside the circuit breaker (AB).

In addition, according to generally accepted safety standards today, installing AVs with a rated current of 25 A on socket groups (and even more so on lighting groups) is bad form. Indeed, with such AB ratings and wire cross-sections (2.5 mm2 for aluminum), the operation of electrical wiring becomes unsafe. The wires will be periodically heated, which will not improve their properties.

In addition, the condition of the twists, terminals and contacts over more than 30 years of operation is, to put it mildly, not very good. In other words, the transition resistances in this electrical installation are increased uncontrollably.

And this, in turn, leads to a low short-circuit current, which I recently measured using improvised means. The current in the apartment turned out to be very low - about 170 A. Why low short-circuit current is dangerous, read my other article.

There were no plans to change all the wiring, so to increase safety, it was decided to install new AVs with lower ratings.

A few more links if the topic is interesting.

  • Everything about the characteristics of circuit breakers, with examples and GOST standards.
  • How modern circuit breakers work from the inside.
  • Everything related to the installation of machines and other devices
  • All articles about power supply - meters, generators, stabilizers, etc.

What is a machine gun

  1. Cocking handle. Brings the device into working condition. If necessary, you can also turn off the machine yourself by moving the lever to the bottom.
  2. Enabling mechanism. Located inside the case.
  3. Contacts. They are intended to close and open a circuit.
  4. Clamps. Connect to a device that provides protection.
  5. Mechanisms. This is a temperature-triggered release plate. Having a bimetallic base. Many machine designs have a current adjustment screw.
  6. Arcing chamber. It may be located inside, in different poles of the machine.

AB25M circuit breakers made in the USSR - what's inside?

To be honest, I put off writing this article for a long time, until I was prompted to do so by a reader from Zen, who left a comment on the article about Crash and trash in the electrical panel of a Taganrog dorm:

– The modern ones are losing to the old Soviet ones. The only plus about the new ones is good clamps. Here the new ones win.

– In what ways do the new modern ones lose to the Soviet ones, who worked for 30 years?

- In many ways. Live parts are iron. The contacts are scanty, we haven’t seen any silver. When turned on, there is no clear and quick turn on (click). Those. the contact is made slowly, under the action of the operator’s finger, and is not thrown by a spring. It ends up burning. The arc chamber is funny and small. The distance between the contacts in the off state is also small. Not for inductive loads. The body is not thermoset plastic, but regular meltable plastic. The ebbs in it for fastening the mechanism elements are weak. Also, mechanics with plastic parts are unreliable. Already when buying in a store you come across defective ones. Switching on fails. As a result, the resource is low. In general, we saved on everything.

This hurt me, and I decided to carry out my plans, having received such a peculiar kick)

I already wrote about the disadvantages of modern circuit breakers in the article Automatic and fuse - what's the difference?

So, AB25M assault rifles. Such switches were previously used in all Soviet apartments, except that Siemens installed them in elite ones.

AB25 M Soviet circuit breakers

Isn't it very brutal?

Terminals, bottom view. The rating is very low((

AB25 25A side view of the nameplate. I wonder why the release characteristic is not indicated? )))

The year of manufacture is the same as mine. I came across 3 machines, but it seems that one of them was made using different molds. The only obvious difference was in the degree of protection - IP10, IP20. I took apart both of them - I didn’t see any differences in IP.

The lower terminals are nonsense, they burn and rust, which is basically the same thing

As you can see, the terminals are the weakest point of these AVs.

I wonder where they copied and pasted them from? The Germans?

Above the bottom terminal there are screws for adjusting the thermal release. I talked about these on my Zen, in an article about regulation in modular circuit breakers, which no one knows about.

By the way, here is a screw with the same functionality in the AB Schneider, which I installed as a replacement:

Release adjustment screw, under the terminal

Let's look at:

Disassembling AB25M

The rivets (bushings) are very powerful, made of thick metal. Drilled it out with a 4.5 drill.

The mechanism is on:

Soviet machine gun from the inside

Now this is crazy, but there is no electromagnetic release inside at all! This suggests that even with a short circuit with real values ​​(hundreds of amperes), the shutdown will take several agonizing, hot, fiery seconds! During this time, everything that is possible will burn out and melt! Conclusion – there is zero fire danger!

I removed the arc chute. Closed contacts visible

AB25M, arc chute closer

We completely disassemble, spare parts are in sight:

We look at the AB25M contacts - they say they are made of silver! didn't check.

It can be seen that this machine hardly had to open during overcurrent - the contacts are almost clean. For more than 30 years of work! By the way, they say that AB25 assault rifles have a fairly high content of precious metals, and they are hunted, who knows. I don't know, so it all went in the trash.

On the bimetallic plate it is written: “NICKOVAR”. Who knows what this means? Where is the bimetal produced?

How does this fire-hazardous miracle of Soviet electrical engineering work? Explanatory picture:

Operating principle of the Soviet circuit breaker AB25M

The bimetallic plate bends under the influence of current (movement 1) and disengages the lever (2), at the other end of which there is a moving contact. By the way, when manually disengaged, disengagement does not occur.

The lever rises under the action of the spring and pushes the getinax indicator plate (3) out.

In this case, the lever remains on, as in the photo. There is not even a “Trip” position, as in some powerful machines. To cock and turn on this machine, you need to guess! click that invisible brown flag. Then the bimetallic plate and the movable contact lever will engage, and the machine is ready for operation. But it is not exactly)))

Honestly, there may be silver in the contacts of Soviet switches, but after this analysis I still trust modern machines more than ancient ones!

Therefore, my advice to you is that if you wanted to change the Soviet machine guns in your dashboard, let this article be for you at the same time a push, a magic kick and a sign from above!

Photo of the placement of machines in the electrical panel