Which cable to buy for a video surveillance system - types and main characteristics.

Coaxial cable

RK-75-1,5-11
RK-75-2-11

rk75-4-11

Coaxial cable boasts the widest distribution and popularity. Inside it there is a copper core, surrounded by a layer of foam dielectric, covered, in turn, with a special protective shell (screen).

The purpose of the shielding layer is to prevent the negative effects of interference during signal transmission. Common types of coaxial cables used in the installation of video surveillance systems include products of the RK series, namely 75-2-13, 75-4-12, as well as a number of analogues of foreign manufacturers of the RG series - 6, 11 and 59.

When choosing a cable, consider the following features - the installation location, as well as the required length. If the video camera is located at a great distance from the recorder (beyond 250-300 m), the signal may weaken during transmission. It is worth remembering here that the thinner and longer the cable, the more significantly the transmitted signal is attenuated.

Consider a number of recommendations regarding the product used and the length of the gasket:

  • RK-75-1.5-11 is used if the distance to the video camera does not exceed 50 m.
  • RK-75-2-11 is suitable at a distance of 300 meters from the recorder.
  • RK-75-4-11. The use of this cable is allowed when the video camera is located at a distance of 600 m from the fixing device.

As for foreign analogues, such as RG-59 or 6U, they can be used at a distance between the recorder and video camera of 600 and 650 m, respectively. To avoid mistakes when choosing, it is important to carefully study the characteristics of the cable and take into account the features of its installation.

Pay attention to the material of the center conductor - it should be made of copper. If this is not the case, the transmitted signal will be too weak. In addition, when choosing, focus on the following characteristics:

  • Flexibility. If during the installation process you plan to bend the product at several points, it is advisable to buy a cable with a multi-core “core”, which allows you to bend it without the risk of damage.
  • Anti-interference level (shield must be provided).
  • Resistance (wave). There are two options here - 50 and 75 Ohms. When installing a video surveillance system, a cable with a rating of 75 Ohms is used.
  • The degree of signal attenuation.

The advantages of coaxial cables include noise immunity and versatility. They can be used to transmit audio and video signals. Disadvantages include the need for high costs for the purchase of connecting devices (connectors), fragility and restrictions on the length of the gasket.

Structure and visual differences between different cable brands:

The central conductor is single-core or stranded. Aluminum foil is used for the technical screen. The second and main screen is stranded copper braid, tinned copper is also used (RG-6 in the image).

The dielectric material used to make cables is most often cellular polyethylene; the honeycombs are formed by air bubbles. A cable with such a dielectric has less mass and less damping (suppression of vibrations), but is more susceptible to mechanical damage.

A general-purpose coaxial cable with a polyethylene foam dielectric can be operated at temperatures from -25 to 75ºС without consequences. But its bending radius during installation must be at least five cable diameters.

The most practical cable for signal transmission is a cable with a single center conductor, but if there are many bends in the line, it is recommended to use a cable with a multi-core center conductor.

Crimping tool and connectors for connecting coaxial cable

twisted pair

The use of twisted pair cables became widespread with the advent of computers. This type of cable is used when connecting a PC to the Network, installing digital surveillance cameras, various electronic devices and when creating computer networks. Structurally, a twisted pair consists of eight thin wires, which are combined in pairs and covered with a common sheath on top.

UTP FTP STP

Depending on the design, the following types of such cables are distinguished:

  • UTP is the simplest type of product that does not have a protective screen. This cable has a low price, but it is not resistant to interference, so when laying in close proximity to electrical wiring, it is recommended to use other types (with high noise immunity).
  • FTP is a cable with a common protective sheath of foil. The presence of a screen allows installation in close proximity to the wiring without worrying about interference. During installation and operation, it is important to monitor the integrity of the foil, avoiding excessive bending. External cable protection is provided using solid polyethylene or PVC.
  • STP. A feature of products of this type is the presence of a more powerful screen (copper braid is used). In addition, the conductors in the cable are also made of solid copper, insulated with polyolefin and have a personal foil shield. Fire-resistant polyvinyl chloride is used as external insulation. An STP cable is the best option when the video camera is connected at a distance of more than 90 m from the recorder and in the presence of a lot of interference.

When choosing, pay attention to a number of characteristics - the diameter of each conductor, the speed of information transfer, the type of outer sheath, as well as the number of cores (single- or multi-core).

The advantages of the cable are ease of installation, low cost (when compared with a coaxial product), the ability to transmit a “picture” over a distance of up to 3000 m, as well as wide functionality. The disadvantages are the low level of protection against interference (for some types), as well as the need to install amplifiers when installing video surveillance over long distances.

Technology selection

5 years ago, when there was a question of choosing between analog and ip, everyone tried to go towards full-fledged digital, if the budget allowed, because the resolution of the former barely reached 0.3 megapixels (if you convert 700 lines to MP). Today, the resolution of analog cameras reaches IP values, but of course they still lose in terms of image formation, but in most cases this difference plays a role only on the professional stage, where the issue of the quality of the transmitted image is based on the inability to miss any important detail, for example at the airport. I’m not talking about the budget segment of IP devices, but about the premium class, which has in its structure complex anti-light modules, dynamic noise reduction, and various analytical capabilities.

Analogue or IP?

It’s a complex question that requires a lot of thought; a whole Talmud of articles has been published on our website telling about the advantages of certain things, let’s get to the point.

Need video analytics? → IP; Need not? → Analogue

Need to record to cloud storage? → IP; No need? → Analogue

Repairs have been made, video surveillance is needed, running wires is not an option → IP (Wireless wi-fi cameras)

No knowledge of computer networks? → Analogue; Eat? - IP

Do you need cameras to operate at a distance of 150 to 500 meters without additional amplifiers and complex circuits? → Analogue

Everyone must make their own choice, but it is important to understand that there is a significant difference, for example, in picture quality between a 2 megapixel analog camera with a Sony matrix for 2500 rubles and a 2 megapixel IP camera for 5000 rubles on an incomprehensible Chinese matrix.

Correct supply of voltage to CCTV cameras is the key to trouble-free and long-lasting operation of all systems. It is believed that 12 volts ± 10% should be supplied to the camera; in fact, for some models, operating at 10.8 - 11 volts is not critical, and anything lower or higher leads to rapid breakdown of the device.

Since a voltage drop occurs in the cross-section of the cable over long distances, instead of 12 volts, for example, 9 volts can reach the camera, therefore you need to be able to calculate the resistivity of the conductor in order to predict the voltage value that reaches the device.

Below is a table of voltage values ​​at different distances for different brands of cables.

Combination cable

KVK-V-2

KVK-2P

When connecting analog video cameras, a combined cable is usually used. Essentially, this is the classic coaxial type, which is combined in an insulating sheath with 2 or 4 conductors. It is used to solve the following tasks: connecting a microphone, transmitting control signals, and supplying power to the camera. The disadvantages of a combined cable include the high price and the need to connect the video camera to a separate power supply. On the other hand, it is noise-resistant and can be laid over long distances. The most popular types of devices are KVK-V-2 and KVK-2P.

DVR and hard drive

The DVR is used in both local and remote (combined) video surveillance systems. The latter allow you to simultaneously receive a video image on the screen of a remote computer or mobile device via an Internet connection. You can use a small computer or laptop as a DVR. But given the high power of these devices, we would recommend purchasing special low-current equipment designed for home video surveillance systems.

If you use a 3G modem to transfer data to a remote device, then the computer will be a bad assistant in this case.

Maksimus52 member FORUMHOUSE

On a PC with network access through a mobile operator (with 3G modems), a connection failure often occurs, which cannot be restored without user intervention.

A special DVR should be purchased in such a way that the number of its channels corresponds to the number of video cameras in your system.

If the system will use several cameras, and the recorder has only one network input, then the connection of the cameras and the video recorder must be made through a POE switch (Switch, also called a hub), which can simultaneously serve as a power supply for the video cameras.

If you decide to install a combined video surveillance system, then a DVR that supports P2P technology is exactly what you need. It will allow you to simultaneously record and monitor an object via the Internet. Remote monitoring will be carried out without connecting to a static IP address and without the need to perform complex settings on your home router. For these purposes, software offered by the device manufacturer and a special service are used. Some call the P2P service cloud, but this is not entirely true, since the system does not allow storing, but only viewing information from video cameras through various devices.

Denispnt FORUMHOUSE member

The method is P2P “cloud”. The cloud does not require a “white” IP. For it, the usual dynamic one, which we use in modems of cellular operators, is sufficient. The DVR interacts with the corresponding website and the user, knowing the unique ID number of the device, connects to it through this website. It is clear that in this case the registrar MUST support this service. NOTHING IS STORED IN THE “CLOUD”! This service acts only as a free communication scheme. All information is written only to the registrar! From there you can watch the recording or download it to your computer or tablet.

To record, we just have to choose a reliable hard drive. The larger its capacity, the longer it will produce continuous recording. If you have more than 2 cameras installed, then it is advisable to choose a disk with a capacity of at least 1 Terabyte. The features of its connection to the DVR will depend on the design of the latter.

If you don't intend to monitor locally, you will still need to connect a monitor to the device to set up the DVR.

For IP video surveillance

UTP cable with RJ-45 connectors

In addition to the USB cable discussed above, another type of product is used for IP surveillance cameras. We are talking about a UTP cable with RJ-45 connectors installed at the edges. The main advantage is the possibility of using one twisted pair cable for the entire video surveillance system with the mandatory installation of a special switch.

In this case, the cameras are powered in one of three ways - by connecting individual cables to each device by installing a power supply or by using unused twisted pair wires. The last method is relevant for cases where the video camera and switch support PoE technology.

Choosing a video camera

Some people may be faced with the question of choosing between analog, WI-FI and IP cameras. Considering the main advantages of the latter, most experts recommend creating home video surveillance systems that are initially equipped with digital equipment.

lambada FORUMHOUSE member

Currently, IP cameras have become cheaper, and it would be reasonable to build a system based on them. Pros: ease of installation and ease of communication, since both the video signal and power can be supplied over cheap UTP twisted pair cable. That is, in this case we save significantly on laying communications. Well, again, IP cameras do not require a video capture card, the software is available in a free version, and the server can be assembled inexpensively. All this can be easily equipped with a UPS that will power both the server and the cameras. The result is an inexpensive, fault-tolerant and high-quality system with simple setup, demonstrating the high quality of the resulting image.

About cameras that transmit signals using WI-FI: read the advice of a specialist who professionally installs video surveillance systems.

Denispnt member of FORUMHOUSE

Wi-Fi in CCTV systems is EVIL! I advise you not to use or design such systems. They demonstrate poor resistance to interference, zero control of signal reception, and equipment freezes during operation. In addition to everything, Wi-Fi is now accessible to almost any student. But such a system still cannot be done without laying power cables.

In order for the video camera to clearly record the situation near the observed object at any time of the day (especially in the absence of external lighting), the device must be equipped with infrared illumination.

IP cameras equipped with a motion sensor can save recording hard drive space and your energy costs by only recording when motion is detected. They can operate in various modes (including continuous recording mode).

Useful tips for choosing

In conclusion, we highlight the main recommendations that will help with the correct choice of cable for video surveillance:

  • When installing IP cameras, the best solution is to use a UTP cable with an RJ-45 connector.
  • For analogue video surveillance, the classic “coaxial” is suitable if the distance between the camera and the recorder is no more than 100-300m.
  • In a situation where signal transmission and power supply are carried out via one cable, it is better to use a combined option.
  • If you use a large number of cameras, you should use STP, FTP or UTP cables. Here, focus on distance and the need for protection from interference.
  • For outdoor cameras, use products with a protective shell made of rigid polyethylene. When installing a video surveillance system inside various structures, a cable with a PVC sheath is suitable. If you need to mount an external system, it is desirable that the cable structure has a steel cable, which provides greater strength to the product (relevant if there is an air laying).

Which one is better to choose?


Which cable to choose for a video surveillance system?

Typically, choosing the right type of CCTV cable depends on your specific situation, your desires and the cameras you choose. In the case of IP cameras, this is almost always the unambiguous use of a UTP cable with RJ-45 connectors; analogue video surveillance with a small number of cameras can get by with a regular coaxial cable at distances not exceeding 100-300 meters, and to be able to supply power and transmit signals over one cable it is necessary use either a combined video surveillance cable with power or twisted pair cable. If you have a large number of cameras and longer distances, we would recommend using a twisted pair cable - UTP, FTP or STP cable - depending on the distances, location of use (outdoors, indoors) and sources of interference.

The differences in the location of communications will be that for external cameras it is necessary to use a cable with protective external insulation made of solid polyethylene, and for internal video surveillance systems it can be taken from ordinary PVC. Also, a cable for outdoor installation may have a steel support cable in its design, which is necessary to enhance the strength of the cable when laying the cable through the air (KVK-Pt).

In this article, we tried to analyze as much as possible the question of how to choose the right cable for video surveillance, talked about the main types and their characteristics, tried to highlight in as much detail as possible those design differences that play a major role in choosing the most suitable cable depending on a particular CCTV systems and your preferences. We wish you good luck and hope that this material remains useful to you!

With this they read:

Ready-made video surveillance kits for various needs: selection tips with examples

Power supplies for CCTV cameras

Microphone for CCTV camera: selection criteria, types and current models

Viewing angle of a CCTV camera lens
Did you like the article? Share with friends on social networks!

  1. Ilya
    04/14/2017 at 12:09

    good afternoon!!! The distance to the cameras is 160 meters!!! what cable should I use? did you want a regular home twisted pair cable or is it too far?

    Reply ↓

    Alexander Starchenko

    (Post author)04/18/2018 at 05:25

    Hello, Ilya. You can use a repeater every 80 meters, but AHD and TVI digital cameras would be better. They now have a resolution of up to 5 megapixels, a range of up to 500 meters.

  2. Anonymous

    03/24/2019 at 03:25

    there are laser cameras up to several kilometers

  • Sergey

    04/17/2017 at 12:21

    you need cable RK-75-2-13—100 meters. Is it available and how much does it cost?

    Reply ↓

      Alexander Starchenko

      (Post author)04/18/2017 at 05:34

      Hello, Sergey! The cost of this cable from various sellers ranges from 10 to 30 rubles/meter.

  • Oleg

    07/08/2017 at 17:02

    Thanks informative!

    Reply ↓

  • Sergey

    07/23/2017 at 12:44

    hello, tell me how to connect the camera to the video intercom, the camera has 4 pairs of colors and there are two wires coming out of the video intercom

    Reply ↓

      Alexander Starchenko

      (Post author)08/05/2017 at 17:46

      Hello. Not every video intercom can connect a video camera; read the instructions for the intercom.

  • SafeHome

    08/07/2017 at 11:50

    hello, please tell me, we connected the camera via UTP twisted pair cable, the distance is 10 meters, and the picture is rippling! But at night it doesn’t show!! The cameras were changed, the signal amplifiers were installed, everyone has already changed their minds, there is no electrical wire nearby, everything is connected clearly and perfectly, checked inside and out several times!!! Has anyone come across this?

    Reply ↓

      Alexander Starchenko

      (Post author)08/12/2017 at 12:31 pm

      You need to check using the KVK or RK75 cable, if the ripples stop, then the problem is in the cable, and if not, then the camera needs to be returned under warranty

  • Konstantin

    08/21/2018 at 14:20

    Your symptoms hinted to me that the power supply unit. poor. There is a possibility that there is a power drawdown during the day, and at night due to the backlight there is a complete failure.

  • Alexander

    02/20/2020 at 06:43

    If it doesn’t show at night, then there is a possibility that there is not enough current from the power source and when the LEDs are turned on, the camera falls off

  • Anonymous

    01/03/2021 at 23:17

    Check the operating temperature of the camera, we toiled for a whole week and it turned out that at night the temperature drops below minus 20 degrees and the camera stops working, this also happens, and about the power supply as a possible reason, make sure that it is in order, for cameras designed for 12 volts the operating range is from 11 .3 volts to 14 volts

  • Alexei

    08/26/2017 at 09:31

    Good afternoon. And with what characteristics should you use a UTP cable when connecting IP cameras powered by PoE technology. The maximum distance to the cameras is 40 m.

    Reply ↓

      Alexander Starchenko

      (Post author)09/12/2017 at 10:30

      Good afternoon. For 40 meters you can use any cable, the distance is not long.

  • Elena

    10/18/2017 at 12:22

    Hello, I need to connect 8 cameras on the street, the cameras will be on poles around the area, but I don’t know which cameras need to be taken so that I can use twisted pair, but twisted pair (with foil insulation) but RJ-45, is there such a thing? And how to connect everything into one circuit, hook up the adapters on the branches to the cameras? Thank you.

    Reply ↓

      Alexander Starchenko

      (Post author)10/26/2017 at 07:37

      IP cameras are connected via twisted pair, RJ-45 is a universal connector used in UTP, FTP, STP cables.

  • Lyubov Vladimirovna

    10/25/2017 at 12:12

    Good afternoon! Please tell me I have a cable for IP cameras. They burned out. Can I put analog cameras on these wires? Thank you in advance

    Reply ↓

      Alexander Starchenko

      (Post author)10/26/2017 at 07:40

      Good afternoon, yes you can.

  • Novel

    12/12/2017 at 11:35

    Good day! Tell me, I have a combined cable with power supply of 10 meters, can I extend the cable with a simple antenna to the TV?

    Reply ↓

      Alexander Starchenko

      (Post author)12/13/2017 at 05:23

      Hello. Yes you can, with a resistance of 75 ohms.

  • Vladimir

    12/12/2017 at 22:15

    Hello. I connected the HD-TVI camera to the DVR via twisted pair cable. Distance 10 meters. The signal does not pass through, the recorder does not see the camera. What can be wrong?

    Reply ↓

      Alexander Starchenko

      (Post author)12/13/2017 at 05:24

      Hello, Vladimir. You need to use TVI converters for twisted pair, or connect with a coaxial cable.

  • Aram

    03/11/2018 at 18:30

    Hello, I have a camera with two tulip connectors (yellow and red) and a power connector, please tell me which cable is more suitable for connection. Distance 10 meters.

    Reply ↓

      Alexander Starchenko

      (Post author)04/18/2018 at 05:27

      Hello Aram. A coaxial cable will suit you, maybe with a transition to BNC.

  • Shohruh

    03/19/2018 at 11:40

    Can you tell me how to crimp 2-pair UTP to connect a video recorder and a computer?

    Reply ↓

      Alexander Starchenko

      (Post author)04/18/2018 at 05:28

      A DVR is like a computer. Accordingly, if directly, then a cross connection, if through a hub, then direct crimping.

  • Marcus

    04/05/2018 at 15:06

    Hello, please tell me which of the 8 wires can be used to power IP cameras. There is no PoE, we just saw how 2 wires from UTP are separated and the power supply is simply connected.

    Reply ↓

      Alexander Starchenko

      (Post author)04/18/2018 at 05:28

      Hello. The blue pair is entirely for minus power, the brown pair is for plus power. Direct crimping (hub-computer).

  • Alexander

    04/15/2018 at 18:03

    Good evening, please tell me. 3ip cameras are connected to the switch. From the candle there is a loco transmitting point at a distance of 200 meters. We use UTP cable on the cable. What problems might arise? Will distance affect signal transmission?

    Reply ↓

      Alexander Starchenko

      (Post author)04/18/2018 at 05:25

      Hello, Alexander. It is better to use a response point not loco, but a full-fledged one in bridge mode. And you need direct visibility. There should be no other problems, the scheme is working.

  • Alexander

    05/17/2018 at 22:13

    Is it possible to run a KVK cable underground in a metal pipe at a distance of 70 meters?

    Reply ↓

      Alexander Starchenko

      (Post author)05/22/2018 at 10:15

      It is possible, as long as the pipe is sealed. Usually HDPE pipe is used, it is without seams.

  • Alexander

    05/19/2018 at 07:45

    Hello. I connected the KPC-EX190SHB1(H-Res) video camera. The camera shows well, but does not last long. The camera soon becomes very hot and wide black stripes appear in the video. The instructions say that it is important that the current is no more than 80mA.

    Reply ↓

      Alexander Starchenko

      (Post author)05/22/2018 at 10:14

      Hello. In the early 2000s, there were cameras that operated only in pulse mode, based on a motion sensor; the same ones were used in video intercoms; they were a little cheaper. You either have a camera malfunction or a pulse camera. It is better to replace it with a more modern AHD.

  • Yuri

    05/19/2018 at 12:15

    Good day, the problem is this: the object has been adjusted, 15 cameras need to be installed, but the cameras are used, the distance to the farthest camera is 300-350 meters, do I need to install amplifiers and at what distance

    Reply ↓

      Alexander Starchenko

      (Post author)05/22/2018 at 10:13

      We tested it on AHD Space technology cameras, the cameras worked normally at a distance of 250-320 meters. These cameras are currently on sale in May and cost 850 rubles each! They have a resolution of 1 megapixel, naturally colored, with night illumination, outdoor, with a stated distance of up to 500 meters. It would be better to replace analog cameras with long-range ones.

  • Michael

    05/23/2018 at 10:28

    Good afternoon I bought 6 ST-1045 AHD cameras, I’m trying to connect via twisted pair, the signal doesn’t come to the recorder, I bought passive transceivers, it still doesn’t work. What can be wrong

    Reply ↓

      Alexander Starchenko

      (Post author)05.25.2018 at 07:24

      Good afternoon. ST-1045 cameras are connected via coaxial cable: RK-75, KVK or similar. If you do not have the opportunity to use coaxial, then at your own peril and risk you can connect twisted pair cables through specialized transceivers for the AHD signal. Transceivers for analog signals are not suitable. And remember that this combination very strongly picks up any interference, for example from a 220V network. Therefore, place the twisted pair cable as far as possible from the source of interference (other cables). In addition, make sure that the recorder input is turned on in AHD mode

  • Alla

    05/24/2018 at 13:40

    Good afternoon Is it possible to use an SFTP cable to connect cameras by laying it in a pipe underground?

    Reply ↓

      Alexander Starchenko

      (Post author)05.25.2018 at 07:27

      Good afternoon You can use a sealed pipe, for example HDPE.

  • Rinat

    05/25/2018 at 19:15

    Good afternoon. There is a need to create a temporary video surveillance system at the site. 10 cameras. Distances from the recorder from 30m. up to 600m. The question is what is the best way to do it (cameras on poles, power will not be supplied to the poles).

    Reply ↓

      Alexander Starchenko

      (Post author)05/27/2018 at 09:24

      Hello, Rinat. Clarify your question, what do you mean when you say “what is the best way to do it?” What cameras are you going to use - analogue or IP?

  • Dima

    05/27/2018 at 16:38

    Hello, is it possible to connect several cameras on one shielding wire and the central wire separately? Thank you.

    Reply ↓

      Alexander Starchenko

      (Post author)05/28/2018 at 05:24

      What cameras are you going to connect? In general, the grounding conductor can be combined.

  • Denis

    06/01/2018 at 23:40

    Hello, we have an IP camera with a distance of 250m. The recorder does not see it, the cable rings and the power comes to the camera. The camera is registered and tested on a short cable. The switch produces three short signals with a pause and repeat. What should I do? Thank you in advance

    Reply ↓

      Alexander Starchenko

      (Post author)06/02/2018 at 06:09

      IP cameras operate at a distance of 80-100 meters. At 250 you can use AHD cameras. If you want IP, then an option is repeaters every 80 meters or WiFi with line of sight.

  • Vitaly

    06/19/2018 at 07:09

    Hello, I have a building with 2 floors plus a roof with metal tiles, I’m going to install a total of 10 cameras inside and outside the building and one on the metal tiles, the question is which cable is better to take, just UTP and with braid, then on the floor for each camera I’m like this I understand that grounding needs to be done, I’m also going to install a passive poe injector with 16 ports to power these cameras, and then take one wire from the injector to the receiver, the distance to the cameras will be no more than 100m, thank you in advance

    Reply ↓

      Alexander Starchenko

      (Post author)06/30/2018 at 11:14

      Hello. You have a wrong idea about the camera connection diagram. More than one wire will come from the injector. If you can provide an approximate diagram of the installation of cameras with marked places, we can make you a commercial offer. What does it mean that I plan to install a camera on a metal tile? Cameras are not installed on metal tiles; you will create a leak in the roof.

  • Alexei

    06/19/2018 at 23:08

    Dear time of day! SNT, we want to install a video surveillance system at the beginning of 4 streets. From 30 to 200 meters to the registrar 0. The lines are supposed to be pulled along 0.4 kV power poles. Install the recorder next to/inside the PTS. It is advisable to turn on motion sensor cameras and at least one microphone. What are your recommendations for equipment? Thanks in advance for your answer

    Reply ↓

      Alexander Starchenko

      (Post author)06/20/2018 at 13:39

      A total of 300 m of cable was laid. In your case, you can either save money by installing general-view cameras, or (which is preferable) install narrow-angle cameras to view each street in the distance. The latter, with a resolution of 2MP 12mm, will cover up to 30-40 meters in length. If we take similar ones with a focal length of 50mm, then their maximum operating range will be up to 200 meters.

      But these cameras will no longer be able to see the 20 meters closest to the camera. Of course, such narrow-angle cameras are more expensive, 12,000-19,000 per unit. It is not advisable to install microphones outdoors; moisture condensation quickly damages them. Or are you planning indoors? If you are interested in equipment, call the phone number listed on the website.

  • Elyar

    08/02/2018 at 09:46

    Hello. They gave me a regular analog camera, I installed and ran a regular military field wire twisted (black), the distance of 45 meters shows dimly and in the evening nothing at all, I installed the electrical power next to the camera. The image has not improved, please tell me what am I doing wrong and do I need to install the power supply nearby? Thank you in advance, I'm waiting for your answer.

    Reply ↓

      Alexander Starchenko

      (Post author)08/07/2018 at 12:48

      Hello. It is better to use a KVK combined cable. A high-quality cable that allows you to transmit power up to 60 meters and a video signal up to 500 meters costs ~ 35 rubles/m. KVK cable with 0.5mm or thinner cores costs 21 rubles/m, up to 40 meters power supply, video up to 300m. But maybe it will work at 45, we need to check. Field cable P-274, field is a telephone cable, it is not intended for transmitting a video signal. As a last resort, you can use the RK-75 cable for video transmission (television).

  • Dmitriy

    08/08/2018 at 14:49

    Hello, there are 4ip 4 MP cameras with Poe, installed on the street, at a distance of 30-150 meters approximately from the DVR. I realized that I needed an external twisted pair cable. I looked, prices range from 19 to 80 rubles per meter. Do I need to buy a screen and what kind of twisted pair cable so as not to overpay for the brand?

    Reply ↓

      Alexander Starchenko

      (Post author)08/28/2018 at 06:36

      Hello Dmitry. A twisted pair connection works up to 80 meters (up to 100 in theory). We tried for a longer distance, the solution is: 1. Use a POE extension cable and 2. Use a P-296 cable.

  • Andrey

    08/12/2018 at 01:28 pm

    Which cable should I use for microphones in a video surveillance system?

    Reply ↓

      Alexander Starchenko

      (Post author)08/13/2018 at 11:31

      Regular twisted pair cable will do.

  • Arthur

    08/12/2018 at 13:45

    There is a need to connect a camera at a distance of 500 meters, the recorder is a hybrid, it is possible to install an AHD or YR, but there is no power supply at the camera installation site. There is a solution?

    Reply ↓

      Alexander Starchenko

      (Post author)08/28/2018 at 06:35

      Hello Arthur. It is necessary to use a KVK cable with low attenuation. We tried. In principle, 4 MP AHD at 600 meters also works, but the quality of course deteriorates. We can produce a kit with power converters for such a distance. Do you already have equipment or will you be purchasing it?

  • Ivan

    08/23/2018 at 13:42

    Good afternoon. Tell. At a distance of ~260-270m from the recorder to the camera, which is better to use a cable for signal and power supply FTP with adapters or KVK? Camera 2MP HD-TVI. Thanks in advance

    Reply ↓

      Alexander Starchenko

      (Post author)08/28/2018 at 06:33

      Good afternoon, Ivan. For 2MP only KVK and high quality, with dense copper braiding. FTP only covers a short distance and is very susceptible to interference.

  • Novel

    09/02/2018 at 09:09

    Good afternoon Alexander, sorry for the trouble, I’m installing a system for 16 cameras, everything is fine, but 8 lines are excessive in length, from 100 to 200 meters, my plan: RG59 combined cable and power supply 9 outputs 12V 30Am, output power 300-400 watts, I am plagued by doubts at such distances; will the losses be critical? , cameras with backlight 12v 2am 8 watt (manufacturer’s data), there is an idea to take a 13.8v unit, measure the output and if you install a converter for 12v, on RG59 there should be no loss of video signal (in theory), please advise what can be changed or implemented to avoid fatal errors. thanks in advance

    Reply ↓

      Alexander Starchenko

      (Post author)11/20/2018 at 07:28

      Good afternoon, Roman! For such a distance, 13.8 V is not enough. Set it to 24 volts or 36. And 8 converters for 12 V. The cable is better than 0.75 mm.

  • Sergey

    09.14.2018 at 15:15

    Good afternoon. Tell . To connect 2 outdoor video cameras, I bought 2 separate cables UTP 4PR 24AWG CAT5e OUTDOOR, 305m CCA PROCONNECT 26 meters each, I don’t know yet what kind of cameras they will be. The cables need to be laid now, SO I’M THINKING to leave it this way or add a separate power cable to each camera so that there is no interference. Or will a UTP 4PR 24AWG cable be enough for both power and video and the picture quality will not suffer?

    Reply ↓

      Alexander Starchenko

      (Post author)11/20/2018 at 07:30

      Hello, Sergey! It is better to use a combined cable for video surveillance, for example KVK. Yes, it is more expensive, 20-40 rubles per meter. But cameras start from 800 rubles apiece and up to 8 megapixels. High-quality street 0.75 mm costs 35 per meter. Via UTP, if you connect AHD cameras, don’t add anything, interference is still possible. And the quality will still drop sharply. You can connect IP POE cameras, but they are much more expensive (from 4000 rubles) with the same quality. They are also more difficult to configure; there are delays during transmission.

  • Yuri

    10/04/2018 at 05:17

    Hello, Alexander. I want to install video surveillance with IP cameras, but the problem is in a cold climate (I live in the far north). The house is private, but I don’t want to drill extra holes for cables. Is it possible to combine cameras on the street and run them into the house with one twisted cable? Please tell me what should I do?

    Reply ↓

      Alexander Starchenko

      (Post author)11/20/2018 at 07:31

      Good afternoon, Yuri! You can if you put the POE switch in an insulated cabinet.

  • Eugene

    10/05/2018 at 10:15

    Good afternoon, please tell me, is it possible to connect 2 IP cameras with separate power to one FTP cable?

    Reply ↓

      Alexander Starchenko

      (Post author)11/20/2018 at 07:32

      Good afternoon, Evgeniy! If the power supply is separate and the cable has 8 cores, then yes, it is possible.

  • Sergey

    10/09/2018 at 15:27

    Good afternoon, please advise: camera 3.0 Mega pixel AHD-H at 100 meters, twisted pair with foil insulation, huge interference, do you need grounding? Or is the cable not suitable?

    Reply ↓

      Alexander Starchenko

      (Post author)11/20/2018 at 07:33

      Good day, Sergey! The cable does not fit. You need a high-quality KVK (outdoor) cable.

  • Dmitriy

    10/22/2018 at 17:03

    Hello! Please tell me which cable can be run under water? Needed for underwater video shooting, preferably armored.

    Reply ↓

      Alexander Starchenko

      (Post author)11/20/2018 at 07:34

      Hello Dmitry! You can use an outdoor KVK with thick insulation. For additional protection, you can place it inside a HDPE pipe (it will only tend to float) or a corrugated metal sleeve.

  • Vladimir

    02/27/2019 at 11:01

    Good afternoon!! Thank you for a very useful, short course. Former engineer. But nevertheless...advise, if possible...advise...! I have analog cameras... the cable is coaxial with power wires. They work well. There is an opportunity to replace them with “IT”... is it possible to use previously laid cables... or do they have to be replaced with twisted pair...? Sincerely!

    Reply ↓

      Alexander Starchenko

      (Post author)03/23/2019 at 09:54

      Use modern AHD cameras, then you won’t have to change them if the cable line is in good condition.

  • Sergey

    05/17/2019 at 16:36

    Analog cameras are located at a distance of 800-1000 meters. The old cable, twisted pair, became unusable under the influence of sunlight. Everything looks good, but the insulation crumbles when touched.

    Reply ↓

  • Cable variety. Why is the right choice so important?

    The technology used to transmit video signals from one location to another is one of the most important components of a CCTV system. The market offers many solutions for connecting components into a single whole. Here are some popular options:

    • twisted pair network cable;
    • coaxial cable and its varieties;
    • high-tech fiber optic cables;
    • wireless video transmitters and receivers.

    A faulty camera can be replaced under warranty. Freezing DVR - reconfigure. Network connections are easy to reconfigure. But if, after installation, an inexpensive and seemingly simple cable refuses to work, then you will have to first find the problem and then start all over again.

    The article will tell you how to choose such a cable, the intricacies of installation, connections and permissible distances. The “picture” will definitely appear on the screen even from a camera several hundred meters away, if you study the tips given. An additional bonus is recommendations for connecting a TV, monitor and other popular devices to video surveillance. Although the article is intended for a non-specialist user, we will be glad if an experienced professional learns something new for himself.

    Features of cables for street video surveillance


    External laying of cables in the ground is done using metal or plastic pipes. If you need to lay an overhead communication line to connect an outdoor video surveillance camera, you must use a video surveillance cable with a cable that protects it from various mechanical loads. Operation of wires and cables of street video surveillance systems occurs under the following conditions:

    • Variable temperatures;
    • High humidity;
    • Exposure to various mechanical loads and ultraviolet radiation.

    All these factors must be taken into account when choosing cables for outdoor installation. On the reliability of video surveillance and methods of installing cable infrastructure. The following options can be distinguished:

    • Laying cables along walls and other supporting structures;
    • By air with suspension on a supporting cable;
    • In pipes and trenches underground.

    In addition to transmitting the video signal, it is necessary to provide power to outdoor video cameras. Therefore, we choose the most suitable cables for this.

    Installation of video surveillance with analog cameras

    Before you directly install video surveillance in your home, you need to draw on paper the locations of video points, cable laying locations, etc.

    In order to maximize coverage of the entire space around the house, it is necessary to install at least one camera on each wall. It wouldn’t hurt to put another one on the roof in front of the front door.