Problems with unstable centralized power supply are solved by purchasing a generator. The equipment is presented on the market in three versions - with manual start, electric starter, and automatic start.
Manual and electric devices are much cheaper in price, but the latter are easy to use.
They differ in design, including a fuel generator (engine, tank, rotor and other elements) and an automatic transfer switch (control unit, mechanism for switching the central power supply to an autonomous one).
The main advantage of generators with automatic transfer switch is instantaneous switching on in the absence of current in the general network.
The article provides an overview of the best models with autostart, based on owner reviews.
How to choose and what to pay attention to?
The recommendations are as follows:
- Decide on the type of power plant . There are petrol, diesel and gas. Gasoline generators are attractive due to their compact size, low noise level, trouble-free operation at low temperatures, and a wide power range. Diesel engines are professional devices, so they are more often used in production. Gas engines are economical in terms of fuel consumption. Petrol and gas generators are perfect for household needs.
- With power . The indicator starts at 1 kW. For domestic conditions, a model with a power of 1 to 10 kW would be a good option. If you need to connect more powerful equipment, then it is worth purchasing a generator with a power of 10 kW or more.
- Pay attention to phasing . Devices are single-phase and three-phase. The first types are intended for connecting only single-phase users, the second - single-phase and three-phase. Models with a voltage of 380/220 V are in demand because they can be used to carry out complex construction work.
Hyundai HHY 10000FE-3 ATS
- Fuel type: gasoline AI-92
- Number of phases: 3×380V
- Engine type: 4-stroke
- Engine capacity: 460 cm³
- Rated power: 7.5 kW
- Maximum power: 8 kW
- Cooling: air
- Fuel tank capacity: 25 l
- Start type: manual/electric
- Sockets: 1x16A, 1x32A
- Weight: 89.5 kg
The Hyundai HHY 10000FE-3 ATS gasoline generator for domestic and professional use is capable of supplying country houses and construction sites with electricity. Consumers with high starting current (for example, concrete mixers) and a total power of up to 8.0 kW can be connected to it.
Switching from 380 volts to 220V and back is provided by the built-in power switching function. The automatic regulator successfully copes with voltage surges and protects against short circuits. The working tools of consumers will not be damaged in case of unstable power supply. The fuel reserve in the fuel tank is enough for 14 hours of operation at 50 percent load.
The self-resetting mechanism will close the cover to protect the socket from construction dust or dirt. A display and an hour meter are installed on the front side.
Rating of the TOP 13 best models
Place | Name | Price |
TOP 7 best gasoline generators with auto start | ||
1 | Hyundai HHY 7020FE ATS | 50 000 ₽ |
2 | Hyundai HHY 10000FE ATS | 58 000 ₽ |
3 | Hyundai HHY 10000FE-3 ATS | 58 000 ₽ |
4 | BISON ZESB-6200-EA | 52 000 ₽ |
5 | Huter DY8000LXA | 50 000 ₽ |
6 | Huter DY6500LXA | 41 000 ₽ |
7 | Daewoo Power Products GDA 8500E-3 | 59 000 ₽ |
TOP 3 best diesel generators with auto start | ||
1 | CHAMPION DG6501ES+ATS | 70 000 ₽ |
2 | MVAE AD-18-400-AR | 300 000 ₽ |
3 | MVAE AD-80-400-AR | 700 000 ₽ |
TOP 3 best gas generators with autostart | ||
1 | Generac 6520 | 195 000 ₽ |
2 | BRIGGS & STRATTON G60 | 200 000 ₽ |
3 | Generac 7145 | 375 000 ₽ |
ATS or generator with additional function
Automatic start of the generator during power outages is implemented in one of the following ways:
- By purchasing a separate ATS unit and coordinating its operation with a generator already in the house that does not have this option.
- Using a generator device model with the ATS function.
Each of these options has its own advantages and disadvantages. In the first case, you will have to put up with additional costs with minimal benefits. The second approach seems more preferable, since you can save significantly on it without losing the quality of the device.
If the purchased generator has an electric starter, you can do without the ATS. To transform it into a generator with an automatic transfer switch, the design will need to be modified.
The best gasoline generators with autostart
Hyundai HHY 7020FE ATS
Power plant with professional air-cooled Hyundai ІС390 engine . Universal single-phase, synchronous technology is perfect for use at home and in the professional field.
The built-in automation system allows you to instantly start the system during a power outage.
It is distinguished by the presence of an original engine, which, according to users, is the most economical in the world.
Characteristics:
- engine capacity - 389 cubic meters. cm, power - 13 l. With.;
- tank volume - 25 l;
- active power - 5 kW, max. — 5.5 kW;
- sockets - 2 for 220 V, 1 for 12 V;
- dimensions - 73x60x57 cm;
- weight - 81.5 kg.
Advantages:
- reliable overload protection;
- control panel with voltmeter and hour meter;
- suitable for intensive loads;
- low noise levels;
- economical fuel consumption;
- sufficient power;
- copper winding of the alternator.
Flaws:
- No.
Hyundai HHY 10000FE ATS
High-performance, single-phase generator based on the Hyundai IC460 air-cooled engine system . It is used in everyday life, organizations, construction, and repairs.
Equipped with a capacious steel fuel tank, hour meter, digital display, and automatic voltage regulator.
The unit is installed on a metal frame with a diameter of 32 mm, which protects it from various damages.
The muffler is easy to remove and change if necessary.
Characteristics:
- engine capacity - 460 cubic meters. cm, power - 18 l. With.;
- tank volume - 25 l;
- engine performance - 1,500 h;
- active power - 7.5 kW, max. — 8 kW;
- sockets - 1 for 220 V, 1 for 12 V;
- dimensions - 75x62x59 cm;
- weight - 89.5 kg.
Advantages:
- overhead valve arrangement on the engine;
- increased engine life;
- Autonomous operation at part load is 14 hours;
- light version of autorun;
- low gasoline consumption;
- AVR voltage regulator;
- copper winding of the alternator.
Flaws:
- No.
Hyundai HHY 10000FE-3 ATS
Three-phase generator with automatic system start . Developed on the basis of the Hyundai IC460 air-cooled engine system.
Equipped with an intuitive panel for assessing operating parameters.
Display includes voltmeter, hour meter.
The power plant immediately turns on when there is no current in the network, and continues to operate in autonomous mode for up to 14 hours (at 50% load).
The copper winding of the alternator provides excellent protection against dust, moisture, various damages and intense loads.
Characteristics:
- engine capacity - 460 cubic meters. cm, power - 18 l. With.;
- tank volume - 25 l;
- engine service life - 1,500 hours;
- active power - 7.5 kW, max. — 8 kW;
- sockets - 1 for 220 V, 1 for 380 V;
- dimensions - 75x62x59 cm;
- weight - 89.5 kg.
Advantages:
- reliable system protection during sudden power surges in the network;
- low vibration and noise levels;
- the ability to connect several users with different power levels;
- automatic regulator AVR;
- easy start in any weather;
- stable output voltage;
- versatility;
- convenient operation and maintenance.
Flaws:
- No.
BISON ZESB-6200-EA
Single-phase, synchronous model with ZUBR 439 motor, improved air cooling system . The generator is equipped with a muffler and a voltmeter.
The launch occurs using an ATS unit, which can be controlled even by a novice user. Capable of operating in autonomous mode for up to 7 hours on one gas station (at 75% load).
Each outlet has its own protection system in the form of dust- and moisture-proof covers . An additional 12 V output allows you to connect a car battery for charging and other low-voltage devices.
Characteristics:
- engine capacity - 439 cubic meters. cm, power - 15 l. With.;
- tank volume - 25 l;
- active power - 5.7 kW, max. — 6.2 kW;
- sockets - 3 for 220 V, 1 for 12 V;
- dimensions - 87x59x58 cm;
- weight - 94 kg.
Advantages:
- rigid frame body;
- minimum level of vibrations;
- high quality output voltage;
- fast automatic start in any weather;
- overload protection in each circuit;
- cable with terminals;
- durability;
- uninterrupted operation.
Flaws:
- No.
Huter DY8000LXA
This is a powerful, synchronous, single-phase model with automatic start . Based on the Huter 420JF air-cooled engine system.
Actively used as a backup or main power source.
The generator attracted consumers with its compact size, ideal combination of price and quality, and uninterrupted operation.
Has a muffler and a voltmeter on the front panel. The engine is placed in a rigid frame, which serves as a support and protection from various mechanical influences.
Characteristics:
- engine capacity - 420 cubic meters. cm, power - 15 l. With.;
- specific fuel consumption - 374 g/h;
- tank volume - 25 l;
- active power - 6.5 kW, max. — 7 kW;
- 2 x 220 V;
- dimensions - 71x58x57 cm;
- weight - 80 kg.
Advantages:
- reliable overload protection system;
- AVR control unit;
- easy start in any weather;
- universal;
- compact;
- stable output voltage;
- possibility of using gas;
- remote control.
Flaws:
- no hour meter;
- weak battery;
- conflict between remote control and automatic control system.
Huter DY6500LXA
Synchronous, single-phase generator with automatic start system . Equipped with a professional air-cooled Huter 188F engine.
The AVR panel allows you to use the unit as a backup source of electricity, creating an uninterrupted power supply.
A reliable engine with a long service life, a spacious tank, and forced cooling allow the system to operate for 10 hours on one fuel fill..
The voltmeter helps the operator evaluate the current output voltage. The manufacturer has prepared an optional kit in the form of a handle and wheels for convenient movement of the station around the work area.
Characteristics:
- engine power - 13 liters. With.;
- specific fuel consumption - 374 g/h;
- tank volume - 22 l;
- active power - 5 kW, max. — 5.5 kW;
- sockets - 2 x 220 V;
- dimensions - 71x58x57 cm;
- weight - 78 kg.
Advantages:
- ease of maintenance and operation;
- automatic protection system against short circuits and overloads;
- built-in fuel and oil level indicator;
- AVR system;
- quick start in any conditions;
- quiet operation;
- stable output voltage.
Flaws:
- No.
Daewoo Power Products GDA 8500E-3
Three-phase generator with automatic starting system . Equipped with a reliable and durable air-cooled Daewoo series 440 engine.
It is equipped with a durable frame, muffler, and wheels for easy transportation.
The AVR block allows you to determine and control the output voltage.
It is actively used in large industries, construction sites, and at home. Excellent for connecting a wide range of single-phase and three-phase users.
Characteristics:
- engine capacity - 445 cubic meters. cm, power - 18 l. With.;
- tank volume - 30 l;
- active power - 7 kW, max. — 7.5 kW;
- sockets - 1 for 220 V, 1 for 380 V;
- dimensions - 68x54x52 cm;
- 94.1 kg.
Advantages:
- presence of an hour meter, voltmeter;
- stable output voltage;
- durable engine;
- easy activation of the system at low temperatures;
- low noise and vibration levels;
- the side parts are equipped with perforated screens.
Flaws:
- No.
Video description
Generator with autostart for home and garden. Autonomous and practical solution.
Types of ABP
All automatic reserve input blocks can be classified according to the following criteria:
- voltage;
- reserve input sections (quantity);
- type of network (single- and two-phase);
- power.
The connection diagram for automatic generator start can be configured so that not all wiring fed by the main source is started, but only those units where shutdown may be critical. For example, in a hospital this is how an intensive care unit and operating room are connected, and in the private sector a workshop and/or sawmill. This is not difficult to do: when installing the wiring, vital or technically critical blocks are output separately from all the others, so the ABP is inserted directly into this circuit.
ABP device
All automatic generator start systems consist of three main blocks.
- Contactors or terminals for switching input and load circuits;
- Logical and indicating devices.
- Relay blocks responsible for controlling (start/stop) the generator.
ABP can become a lifesaver not only when the main power line is disconnected, but also during voltage dips, which can sometimes occur in suburban areas due to weak transformer substations. That is, the inclusion of a start function in the circuit when the voltage drops to 90% (instead of 220 V - 200 V) of demand. This will allow the electric motors to operate without interruptions and unnecessary load. With this option, generator autostart systems allow you to save on repairs and the purchase of new equipment. The contact group is responsible for starting the reserve circuit, and the input voltage is monitored by the RKF or phase control relay.
The simplest ATS circuit for a single-phase network Source asutpp.ru
Now, using the diagram above, let’s take a closer look at how a diesel or gas generator with automatic start allows you to eliminate dips (complete shutdown or drop) in the voltage from the main power source. Here, too, everything is very simple: when ≈220 V is supplied stably, the phase control relay keeps the terminals in the normal closed state. If there is any breakdown on the power line side, the saturation of the RKF solenoid becomes weak and cannot hold these terminals, hence they open. In those situations where an inverter is present, as indicated in the above diagram, it will begin to generate ≈220 V, which is necessary for the consumer. If the main power cannot be restored within the time set depending on the power of the batteries, then the controller sends an autostart command to the generator.
As soon as the contactor block receives voltage from the main transformer substation, the automatic generator start system operates in the reverse order - the terminals are switched and the entire circuit is powered according to the intended design. To put it simply, the signal when restoring the transformer from the power line gives a command to shut off the fuel hose, be it gasoline, diesel fuel or gas. The valve blocks the fuel supply and the engine stops.
The best diesel generators with auto start
CHAMPION DG6501ES+ATS
Reliable and high-quality, synchronous, single-phase generator with ATS unit . Designed to create a source of electricity at construction sites and remote sites when it is necessary to power various devices, instruments, and tools.
Copper winding of the brush rotor and stator increases the level of protection of the main power unit.
The design is equipped with doors with which you can easily service the generator. The front panel includes a digital display with a voltmeter and an hour meter.
Characteristics:
- engine capacity - 474 cubic meters. cm, power - 8.9 l. With.;
- specific fuel consumption - 320 g/h;
- tank volume - 16 l;
- active power - 5 kW, max. — 5.5 kW;
- sockets - 2 for 220 V, 1 for 12 V;
- weight - 160 kg.
Advantages:
- soundproof casing;
- wheels for easy movement;
- effective protection system;
- ATS block;
- trouble-free start;
- battery included;
- high-quality output current;
- spacious fuel tank.
Flaws:
- No.
MVAE AD-18-400-AR
Three-phase, synchronous generator with automatic start, liquid-cooled K4100 series motor.
A distinctive feature is the SMARTGEN 6120U control panel.
It helps to determine operating parameters much faster and more accurately.
Convenient control with a voltmeter and an hour meter will be a pleasant bonus for every operator. An additional advantage is the increased engine life, reaching 10,000 hours.
Characteristics:
- tank volume - 80 l;
- active power - 18 kW, max. — 19.8 kW;
- there is a muffler, overload protection;
- dimensions - 150x121x72 cm;
- weight - 765 kg.
Advantages:
- an excellent solution for connecting professional equipment;
- powerful engine with increased service life;
- stable output voltage;
- automatic system start;
- intuitive control panel;
- spacious fuel tank;
- long-term work in autonomous mode.
Flaws:
- No.
MVAE AD-80-400-AR
Three-phase generator based on the MVAE 6105AZLD liquid-cooled propulsion system . Equipped with an automatic control system.
Suitable for installation indoors (in a protective casing) and outdoors.
At full load, the unit can operate up to 9 hours on one fuel fill..
Supplemented with a muffler and overload protection. The voltmeter on the front control panel allows you to evaluate the current output voltage.
Characteristics:
- tank volume - 200 l;
- active power - 80 kW, max. — 88 kW;
- current strength - 159 A;
- dimensions - 225x135x90 cm;
- weight - 1,170 kg.
Advantages:
- uninterrupted power supply;
- professional, durable engine;
- convenient operation in large industries;
- many outputs for connecting users;
- stable output current;
- Autonomous operation up to 9 hours at full load;
- economical fuel consumption.
Flaws:
- No.
How to start a gasoline generator?
Each generator starts differently. It depends on what type of launch it is equipped with. There are several ways to enable it:
- Manual. The device must have a special handle that starts the work.
- Electronic. More convenient and simpler activation is carried out by turning the key in the battery built into the housing.
- Auto. Turns on automatically after a drop in mains voltage.
- Remote. To turn it on, a remote control is included.
Before starting, you should study the instructions for use in detail for safety and more efficient operation of the device.
The best gas generators with autostart
Generac 6520
Single-phase generator from the POWER PACT series with an air-cooled engine, automatic control . It will be an ideal option for providing electricity to a private home or cottage.
The generator is based on the GENERAC engine, securely hidden in a noise-proof casing.
You can use bottled or main gas as fuel. For operation at low temperatures, the manufacturer recommends adding a “heating” option to the unit.
Characteristics:
- engine capacity - 420 cubic meters. cm;
- active power - 5 kW;
- current strength - 22.7 A;
- noise level - 60 dB;
- there is a muffler;
- dimensions - 95.7x64.3x68 cm;
- weight - 115 kg.
Advantages:
- low noise and vibration levels;
- easy autostart;
- saving money on fuel purchases;
- long battery life;
- intuitive display with performance indicators;
- additional options;
- soundproof casing;
- stable voltage.
Flaws:
- No.
BRIGGS & STRATTON G60
Single-phase generator based on the Briggs and Stratton Intek I/C air-cooled propulsion system . The power unit has high endurance, easy starting at any temperature, especially in severe winter.
The automatic block allows the structure to turn on as quickly as possible in the absence of current in the electrical network.
The generator is housed in a soundproof casing, which effectively reduces noise and vibration levels.
Characteristics:
- engine capacity - 500 cubic meters. cm;
- active power - 5.4 kW;
- noise level - 72 dB;
- overload protection, muffler.
Advantages:
- operates on any type of gas;
- produces a stable current;
- durable engine;
- efficiency;
- attractive design;
- overheating is excluded.
Flaws:
- No.
Generac 7145
Single-phase generator from the GUARDIAN series . Based on the modern Generac G-Force engine with increased volume, two cylinders and four strokes, air cooling.
Is an excellent option for providing electricity to private homes, businesses, and small industries.
Supplied in a noise-protective casing that reduces noise and vibration levels. To operate the system in automatic mode, it is necessary to supplement the unit with the “automation unit” option.
For starting in cold weather, use the “heating” option.
Characteristics:
- engine capacity - 999 cc. cm;
- active power - 10 kW;
- current strength - 45.5 A;
- noise level - 63 dB;
- muffler;
- dimensions - 122.8x73.3x63.5 cm;
- weight - 176 kg.
Advantages:
- unpretentiousness to intense loads;
- work on any type of gas;
- easy access to main elements;
- attractive design;
- additional options;
- improved version of the engine;
- stable current supply.
Flaws:
- No.
Generator autostart unit
As an automatic input of a reserve, we will consider in more detail the BAZG-1 device, which is a generator autostart unit. With its help, remote control is provided that does not require the presence of people. The main function of the unit is to start and stop the power plant engine. There are five attempts to start, including 5 seconds for the start itself, and 15 seconds for a break between starts with automatic control of the air damper.
The BAZG-1 unit is part of the automatic backup power supply system. An external source issues a command that starts and subsequently controls the operation of the engine. In order for the system to work fully, you will need a shield that switches to reserve.
The BAZG-1 device can work in conjunction with an inverter, which provides starting of the generator and further recharging of the battery. The generator starts and stops by closing and opening two contacts. If the startup attempt is unsuccessful, the unit goes into emergency mode. To exit it, you need to remove power from the unit or cancel the start command. The generator cools down for 30 seconds before shutting down the engine completely.